What was found
FRAME 94.8 FLANGES ARE CORRODED STR 32P-30S. ACFT DOWN FOR C-CHECK. REMOVED RIVETS FOM AND REMOVED CORROSION IAW Q400 SRM 51-42-05-02-01 AND RD 8/4-53-2344. MIN THICKNESS REMAINING .037", CONFIRMED CRACK FREE REF NTM 51-00-02-250-801 PT4 AND 51-00-0-6-910-801. MATERIAL LOSS WITHIN LIMITS IAW RD 8/4-53-2344. ALODINED, PRIMED AND INSTALLED RIVETS IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-42-05-02-01. APPLIED ALUMINIZED PAINT AND CPC IAW RD 8/4-53-2344.