What was found
FRAME 301 FLANGES ARE CORRODED STR 32S-28P. ACFT IS DOWN FOR C-CHECK. REMOVED CORROSION IAW RD 8/4-53-2344. PERFORMED UT THICKNESS CHECK IAW NDTM PT 1, 51-00-04-910-801. CONFIRMED CRACK FREE REF NTM 51-00-06-910-801 PT1. MATERIAL LOSS WITHIN LIMITS RD 8/4-53-2344. ALODINED, PRIMED PAINTED AND APPLIED CPC IAW RD 8/4-53-2344, 51-21-10-02-01, 51-25-10-02-01 AND 51-25-05-02-01.