What was found
FRAME 529.5 FLANGES ARE CORRODED STR 31P-33. ACFT IS DOWN FOR C-CHECK. REMOVED CORROSION IAW RD 8/4-53-2344. PERFORMED HFEC OF BLENDED AREA FOR CRACKS REF NDTM PT1 51-00-06-910-801. NO CRACKS NOTED. PERFORMED UT THICKNESS CHECK OF BLENDED AREA IAW NDTM PT 1 51-00-04-910-801. MINIMUM REMAINING THICKNESS .046". FOUND FLANGES TO BE WITHIN LIMITS IAW RD 8/4-53-2344. ALODINED FLANGES, PRIMED AND INSTALLED RIVETS IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-42-05-02-01. APPLIED PAINT IAW SRM 51-25-15-02-01. APPLIED CPC IAW AMM 51-25-01-390-801. COMPLETED RD 8/4-53-2344.