What was found
FRAME 624.5 FLANGE IS CORRODED STR 24S-23S. ACFT IS DOWN FOR C-CHECK. REMOVED CORROSION IAW RD 8/4-53-2344. PERFORMED HFEC OF BLEND FOR CRACKS IAW NDTM PT 1, 51-00-06-910-801, NO CRACKS NOTED. PERFORMED UT THICKNESS CHECK OF BLEND IAW Q400 NDTM PT 1 51-00-04-910-801. MINIMUM REMAINING THICKNESS OF .062". MATERIAL LOSS FOUND TO BE WITHIN LIMITS PER RD 8/4-53-2344. ALODINED, PRIMED AND INSTALLED RIVET IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-42-05-02-01. APPLIED ALUMINIZED PAINT, CPC AND PAINTED EXTERIOR SURFACE IAW RD 8/4-53-2344.