As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOORBEAM 32.4 IS CORRODED BL0 TO SEAT TRACK 11. ACFT IS DOWN FOR C-CHECK. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS .070", CONFIRMED CRACK FREE REF NTM 51-00-02-250-801 PT 4 AND 51-00-06-910-801. FOUND BLENDS TO BE WITHIN LIMITS IAW RD 8/4-53-4321. COMPLIED WITH TASK CARD RD 8/4-53-4321.