What was found
FRAME 156 AND FLANGE ARE CORRODED BY STR 32P. ACFT IS DOWN FOR C-CHECK. REMOVED CORROSION IAW 51-21-00-00-02. MINIMUM REMAINING THICKNESS .038", CONFIRMED CRACK FREE REF NTM 51-00-02-250-801 AND 51-00-06-910-801. FLANGE FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-2344.ALODINED, PRIMED AND INSTALLED RIVETS IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-42-05-02-01. APPLIED ALUMINIZED PAINT AND CPC IAW RD 8/4-53-2344. RESTORED EXTERIOR FINISH IAW RD 8/4-53-2344.