What was found
FRAME 196 AND THE FLANGES ARE CORRODED STR 30S-32S. ACFT IS DOWN FOR C-CHECK. REMOVED CORROSION IAW SRM 51-21-00-00-02 AND RD 8/4-53-2344. MINIMUM REMAINING THICKNESS .036, CONFIRMED CRACK FREE REF NTM 51-00-02-250-801, PT 4 AND 51-00-06-910-801. FLANGES ARE WITHIN LIMITS IAW RD 8/4-53-2344. ALODINED, PRIMED AND INSTALLED RIVETS IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-42-05-02-01. PAINTED IAW SRM 51-25-15-02-01, APPLIED CPC IAW AMM 51-25-01-390-801.