What was found
STRINGER 32S SPLICE FWD OF FRAME -18.250 CORRODED. ACFT IS DOWN FOR C-CHECK. R & R STRINGER SPLICE IAW SRM 51-42-05-02-01. APPLIED PAINT AND MOISTURE DISPLACING COMPOUND IAW SRM 51-25-15-02-01 AND AMM 51-25-01-390-801.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STRINGER 32S SPLICE FWD OF FRAME -18.250 CORRODED. ACFT IS DOWN FOR C-CHECK. R & R STRINGER SPLICE IAW SRM 51-42-05-02-01. APPLIED PAINT AND MOISTURE DISPLACING COMPOUND IAW SRM 51-25-15-02-01 AND AMM 51-25-01-390-801.