What was found
LONGITUDINAL SKIN STRAP BY STR 32P HAS A SPOT OF CORROSION FR 176-196. REMOVED RIVETS FOM IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02. CONFIRMED AREA CRACK FREE REF NTM 51-00-01-250-801 PT 6. MINIMUM REMAINING THICKNESS .048" FOUND TO BE ACCEPTABLE REF RD 8/4-53-4275. ALODINED AND PRIMED BLENDED AREA REF RD 8/4-53-4275. INSTALLED RIVETS IAW RD 8/4-53-4275. APPLIED ALUMINIZED TOPCOAT, CPC AND EXT. PAINT IAW RD 8/4-53-4275.