What was found
FRAME 604.5, FLANGE IS CORRODED AT STRINGER 31P-32P. REMOVED RIVETS FOR ACCESS TO AREAS. REMOVED CORROSION IAW RD 8/4-53-2344. MATERIAL REMOVED WITHIN LIMITS AND CRACK FREE. RE-INSTALLED RIVETS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.