What was found
FRAME BS 547, FLANGES ARE CORRODED AT STRINGER 33-31S. REMOVED RIVETS TO CLEAN UP CORROSION. REMOVED CORROSION IAW RD 8/4-53-2344. REMAINING MATERIAL WITHIN LIMITS AND CONFIRMED CRACK FREE. INSTALLED RIVETS. .
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME BS 547, FLANGES ARE CORRODED AT STRINGER 33-31S. REMOVED RIVETS TO CLEAN UP CORROSION. REMOVED CORROSION IAW RD 8/4-53-2344. REMAINING MATERIAL WITHIN LIMITS AND CONFIRMED CRACK FREE. INSTALLED RIVETS. .