What was found
STRONG ELECTRICAL ODOR IN AFT GALLEY. REPAIRED BROKEN WIRE AT RT RECEPTACLE. REPLACED GROUND STUD, RECIRC FAN POWER GROUND & APU SHUNT. PERFORMED DVI OF AFT BAGGAGE COMPARTMENT LIGHTS & SOCKETS, NO DEFECTS NOTED. PERFORMED DVI OF AFT GALLEY WORK LIGHT, OVERHEAD LIGHTS, READING LIGHT & INFORMATION SIGNS AS WELL AS ALL SOCKETS ASSOCIATED W/ THOSE LIGHTS, NO DEFECTS NOTED. PERFORMED GVI OF AFT GALLEY CONTROL PANEL. FOUND LT SWITCH ALWAYS ON, R & R LT SWITCH, NO OTHER DEFECTS NOTED W/AFT GALLEY CONTROL PANEL. PERFORMED GVI OF LT & RT MAPCOS & ELECTRICAL TERMINALS. FOUND RIGHT MAPCO RECEPTACLE BURNT & ONE WIRE TERMINAL BROKEN. REPAIRED WIRE TERMINAL PER WM20-12-10. FOUND LIGHT CORROSION ON MAPCO GROUND STUD, REMOVED CORROSION FROM. REMOVED & REPLACED RIGHT MAPCO RECEPTACLE, INSTALLED SERVICEABLE MAPCO & PERFORMED OPS CHECK AS REQ. OPS CHECK GOOD, NO FURTHER DEFECTS NOTED, NO BURNT/ ELECTRICAL SMELL NOTED.