As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
STUB FRAME FLANGE ANGLE BELOW PAX DOOR THRESHOLD HAS CORROSION OTBD OF STRINGER 25P AT STA X28.00. REMOVED FLANGE ANGLE IAW SRM 51-42-05-02-01. MATCH DRILLED NEW ANGLE, ALODINED AND INSTALLED STUB FRAME FLANGE ANGLE IAW SRM 51-40-07-02-01, 51-21-10-02-01 AND 51-42-05-02-01. APPLIED PROTECTIVE COATINGS IAW SRM 51-25-10-02-01, 51-25-15-02-01 AND AMM 51-25-01-390-801.