What was found
STUB FRAME FLANGE ANGLE BELOW PAX DOOR THRESHOLD HAS CORROSION OTBD OF STRINGER 25P AT STA X9.00. REMOVED FLANGE ANGLE IAW SRM 51-42-05-02-01. MATCH DRILLED NEW ANGLE, ALODINED AND INSTALLED STUB FRAME FLANGE ANGLE IAW SRM 51-40-07-02-01, 51-21-10-02-01 AND 51-42-05-02-01. APPLIED PROTECTIVE COATINGS IAW SRM 51-25-10-02-01, 51-25-15-02-01 AND AMM 51-25-01-390-801.