What was found
ON LANDING AND ROLLOUT. GROUND CONTROL STATED THEY SAW SMOKE COMING FROM THE ACFT. STOPPED ACFT. INSPECTED AND OBSERVED A PUDDLE OF FLUID UNDER ACFT. NR 2 HYD QUANTITY FALLING TO ZERO. SMOKE WENT AWAY AND ACFT TAXIED TO THE GATE. F/A B NOTICED A STRANGE NOISE ON FINAL COMING FROM THE REAR OF ACFT. REPLACED THE NR 2 PTU. CLEANED AREA AND FLUSHED SYS. FERRIED FOR MORE MX. COLLECTED HYD SAMPLE. RETURNED TO SERVICE.