Service difficulty report · Warning Light · Bombdr DHC8402

Difficulty date
June 5, 2012
Submitted
June 11, 2012
Operation
Air carrier
Aircraft
N411QX
Make and model
Bombdr DHC8402
Aircraft serial
4055
Aircraft time
26,062 hours, 27,162 cycles
Part
Warning Light
Condition
False Activation
Location
Cabin Pressure
Stage of operation
DE
How discovered
O
Nature of condition
N
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PRESSURIZATION FAULT LIGHT ILLUMINATED DURING DESCENT, RAN CHECK LIST, AFTER PUTTING IT IN DUMP LIGHT WENT OUT. CDS SHOWS FAULTS AFT OUTFLOW VALVE FAIL AND CPC OF VALVE DATA FAIL. FAULTS CLEARED. PERFORMED FUNCTIONAL TEST OF PRESSURIZATION CONTROL IAW AMM TASK 21-31-00-720-801, FUNCTIONAL TESTED GOOD. FAULTS DID NOT RETURN IN CDS. OK FOR SERVICE.