What was found
INTERNAL BELLY SKIN STRAP HAS CORROSION AT STA X49.500 BETWEEN STRINGERS 29S AND 31S. REMOVED CORROSION IAW SRM 51-21-00-00-02. RIVETS PREVIOUSLY REMOVED IAW SRM 51-42-05-02-01. PERFORMED UT THICKNESS OF BLENDS IAW NTM 51-00-04-910-801 PT 1. MIN REMAINING THICKNESS MEASURED .049". CONFIRMED AREA TO BE CRACK FREE REF NTM 51-00-01-250-801 PT 6. ALODINED AND PRIMED AFFECTED AREAS IAW RD 8/4-53-4550. DAMAGE FOUND TO BE WITHIN LIMTS IAW RD 8/4-53-4550 RECEIVED FROM MFG ENGINEERING. INSTALLED RIVETS IAW RD 8/4-53-4550. PAINTED REPAIR AREAS IAW RD 8/4-53-4550. COMPLIED WITH TASK CARD RD 8/4-53-4550.