What was found
STRINGER 29S HAS AREAS OF CORROSION BETWEEN STA 71.200 AND X94.800. REMOVED 30 RIVETS FOM IAW SRM 51-42-05-02-01 BLENDED CORROSION IAW SRM 51-21-00-00-02. PERFORMED HFEC OF BLENDS FOR CRACKS IAW NTM 51-00-06-910-801 PT 1. NO CRACKS NOTED. PERFORMED UT THICKNESS CHECK IAW NTM 51-00-04-910-801, MIN REMAINING THICKNESS MEASURED .063". FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-4577. ALODINED AND PRIMED WORKED AREA IAW RD 8/4-53-4577. INSTALLED RIVETS IAW SRM 51-42-05-02-01. APPLIED CPC, TREATED , PRIMED AND PAINTED EXTERIOR REPAIR AREA IAW RD 8/4-53-4577 STEP 4-6. COMPLIED WITH TASK CARD RD 8/4-53-4577.