What was found
FOUND INTERNAL FUSELAGE AREA OF CORROSION FROM FRAME X94.800 TO FRAME X136.000 BETWEEN STRINGERS 31P AND 32P. REMOVED RIVETS FOM IAW SRM 51-42-05-02-01. BLENDED CORROSION IAW SRM 51-21-00-00-02. CONFIRMED BLENDED AREA CRACK FREE REF NTM 51-00-02-250-801, PT 6. DAMAGE IS IN LIMTS IAW RD 8/4-53-4567. ALODINED AND PRIMED IAW RD 8/4-53-4567. INSTALLED RIVETS IAW RD 8/4-53-4567. TREATED, PRIMED, PAINTED AND COATED REPAIR AREA IAW RD8/4-53-4567. COMPLIED WITH TASK CARD RD 8/4-53-4567.