What was found
FUSELAGE FRAME X71.200 LOWER FLANGE HAS CORROSION BETWEEN STRINGERS 29P AND 31P. REMOVED RIVETS FOM AND REMOVED CORROSION IAW RD 8/4-53-2344. PERFORMED HFEC OF BLENDS FOR CRACKS IAW NTM 51-00-06-910-801 PART 1, NO CRACKS NOTED. MATERIAL LOSS FOUND WITHIN LIMITS IAW RD 8/4-53-2344. TREATED AND PRIMED IAW RD 8/4-53-2344, INSTALLED RIVETS IAW SRM 51-42-05-02-01. APPLIED TOP COAT AND CPC IAW RD 8/4-53-2344.