What was found
CENTER WING UPPER DRY BAY PANEL 521AT HAS AREAS OF CORROSION ON MATING SURFACE. REMOVED CORROSION AND BLENDED DAMAGE IAW RD 8/4-57-425, STEP 1. EVALUATED AND FOUND OUT OF LIMITS. CONFIRMED BLENDS CRACK FREE REF NTM 51-00-06-910-801. FOUND TO BE WITHIN LIMITS OF RD 8/4-57-1859. APPLIED ALODINE AND PRIMER IAW RD 8/4-57-425. INSTALLED SKYFLEX TAPE IAW RD 8/4-57-425. COMPLIED WITH TASK CARD RD 8/4-57-1859.