As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT PAX DOOR MAIN HINGE APPEARS TO BE CHAFED ON LOWER EDGE. BLENDED DAMAGE IAW SRM 51-14-00-02-04. CONFIRMED BLEND CRACK FREE REF NTM 51-00-06-910-801 PT 1. CLEANED, ALODINED, PRIMED AND PAINTED AREA IAW RD 8/4-52-789. MATERIAL LOSS FOUND IN LIMITS IAW RD 8/4-52-789. COMPLIED WITH TASK CARD RD 8/4-52-789.