As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SERVICE DOOR MAIN HINGE LOWER EDGE APPEARS TO HAVE CHAFED AREAS. BLENDED DAMAGE IAW SRM 51-14-00-02-04. CONFIRMED BLEND CRACK FREE REF NTM 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND IN LIMITS IAW RD 8/4-52-796. TREATED, PRIMED AND PAINTED AREA IAW RD 8/4-52-796. COMPLIED WITH TASK CARD RD 8/4-52-796.