What was found
RT ENGINE FWD MOUNT STRUT F3 HAS A GOUGE ON FWD END OF TUBE. SMOOTHED GOUGE IAW SRM 51-14-00-02-04. CONFIRMED BLEND CRACK FREE REF NTM 8.2.1.1. BLEND FOUND TO BE OUT OF LIMITS IAW SRM 51-14-00-02-04. COMPLIED WITH RD 8/4-54-1025.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT ENGINE FWD MOUNT STRUT F3 HAS A GOUGE ON FWD END OF TUBE. SMOOTHED GOUGE IAW SRM 51-14-00-02-04. CONFIRMED BLEND CRACK FREE REF NTM 8.2.1.1. BLEND FOUND TO BE OUT OF LIMITS IAW SRM 51-14-00-02-04. COMPLIED WITH RD 8/4-54-1025.