What was found
FOUND CORROSION ON LT EXTERNAL FUSELAGE SKIN STA 728-783 AT FLOOR LEVEL. REMOVED CORROSION IAW SRM 51-21-00-00-02. PERFORMED HFEC OF BLENDS FOR CRACKS IAW NTM 51-00-01-250-801, PT 6, NO CRACKS NOTED. PERFORMED UT THICKNESS OF BLENDS IAW NTM 51-00-02-250-801, PT 4. MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD 8/4-53-4563. APPLIED ALODINE, PRIMER AND TOP COAT AS REQUIRED IAW RD 8/4-53-4563. COMPLIED WITH TASK CARD RD 8/4-53-4563.