As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FRAME AT STA 94.8 BETWEEN STR 33 AND 28S IS CORRODED. REMOVED JOINT SPLICE IAW SRM 51-42-05-2-01. MATCH DRILLED NEW FRAME MEMBER TO EXISTING STRUCTURE IAW SRM 51-40-07-02-01. ALODINED, PRIMED AND PAINTED AND REAPPLIED SURFACE PROTECTION IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-25-15-02-01. INSTALLED SPLICE IAW SRM 51-42-05-02-01.