What was found
CENTER WING SKIN UPPER DRY BAY LANDING FOR PANEL 521AT HAS AREAS OF CORROSION. BLENDED AND REMOVED CORROSION IAW RD 8/4-57-441. CONFIRMED BLENDED AREAS CRACK FREE REF NTM 51-00-06-910-801. MATERIAL LOSS FOUND TO BE OUT OF LIMITS IAW 8/4-57-441. MATERIAL LOSS FOUND TO BE WITHIN LIMITS OF RD 8/4-57-1850. REMOVED AND REINSTALLED 3 RIVETS IAW Q400 SRM 51-42-05-02-01. ALODINED AND PRIMED LANDING IAW SRM 51-21-10-02-01 AND 51-25-10-02-01. COMPLIED WITH TASK CARD RD 8/4-57-1850.