Service difficulty report · Warning Light · Bombdr DHC8402

Difficulty date
July 3, 2012
Submitted
July 5, 2012
Operation
Air carrier
Aircraft
N444QX
Make and model
Bombdr DHC8402
Aircraft serial
4355
Aircraft time
2,717 hours, 2,757 cycles
Engine
Pwc PW150A
Part
Warning Light
Condition
False Activation
Location
Cabin Pressure
Stage of operation
CR
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FAULT LIGHT ILLUMINATED ON CABIN ALTITUDE CONTROL PANEL. AFTER CONDUCTING CHECK LIST, LIGHT EXTINGUISHED. DIVERTED AND ACCOMPLISHED UNEVENTFUL LANDING. COMPLIED WITH FIM TASK 21-30-00-810-802. CDS SHOWS FAULTS; AFT OUTFLOW VALVE FAIL AND CPC/OF VALVE DATA FAIL ON CPCS PAGE. FAULTS CLEARED. COMPLIED WITH FUNCTIONAL TEST OF THE PRESSURIZATION CONTROL IAW AMM TASK 21-31-00-720-801. TESTED GOOD. OUTFLOW VALVE CHECKED GOOD IN MANUAL MODE. INSPECTED MAIN CABIN DOOR SEAL DURING PRESSURIZATION, NO LEAKS NOTED. ACFT OK FOR CONTINUED SERVICE.