What was found
STRINGER 24S HAS CORROSION AND CORRODED RIVETS BETWEEN STA X116.000 AND X136.000. REMOVED RIVETS (20) AND CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. CORROSION LIMITED TO 20 FASTENERS AND STRINGER SPLICE. MATERIAL LOSS FOUND TO BE OUT OF LIMITS IAW SRM 53-20-03-00-01. MATCH DRILLED NEW SPLICE IAW SRM 51-40-07-02-01. INSTALLED NEW SPLICE IAW SRM 51-42-05-02-01. INSTALLED RIVETS (20) IAW SRM 51-42-05-02-01. PRIMED, PAINTED AND CPC INTERIOR IAW SRM 51-21-10-02-01, SRM 51-25-25-02-01 AND AMM 51-25-01-390-801. PRIMED AND PAINTED EXTERIOR AREA IAW SRM 51-25-10-02-01 AND 51-25-15-02-01.