What was found
STRINGER 3S HAS CORROSION BETWEEN STA X281.000 AND X301.000. CLEANED STRINGER IAW SRM 51-26-00-02-01. REMOVED RIVETS (1) AND CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. PERFORMED HFEC OF BLENDS FOR CRACKS IAW NTM 51-00-06-910-801, PT 1. NO CRACKS NOTED. PERFORMED UT THICKNESS OF BLENDS IAW NTM 51-00-04-910-801 PT 1. MIN REMAINING MATERIAL MEASURED .082". NOMINAL THICKNESS .080" NO MATERIAL LOSS NOTED IAW DWG 85361511. INSTALLED 1 RIVET IAW SRM 51-42-05-02-01. ALODINED, PRIMED, ALUMINIZED AND APPLIED CPC IAW SRM 51-21-10-02-01, 51-25-10-02-01, 51-25-15-02-01 AND AMM 51-25-01-390-801.