What was found
STRINGER 31S HAS CORROSION FWD AND AFT OF STR X116.000. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS .078" REF NTM 51-00-04-910-801 PT 1. CONFIRMED AREA CRACK FREE USING HFEC REF NTM 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND IN LIMITS IAW RD 8/4-53-4608. R & R 4 RIVETS IAW RD 8/4-53-4608 AND TASK CARD RD 8/4-53-4608. APPLIED SURFACE PROTECTION IAW RD 8/4-53-4608. APPLIED SURFACE PROTECTION TO EXTERNAL AREAS IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-25-05-02-01. COMPLIED WITH TASK CARD RD 8/4-53-4608.