What was found
UNDER FLOOR STUB FRAME RE-ENFORCEMENT ANGLE AT APPROX STA X24.000 BELOW FWD PAX DOOR OPENING HAS CORROSION BETWEEN STRINGERS 23P AND 25P. REMOVED CORRODED ANGLE IAW SRM 51-42-05-02-01. MATCH DRILLED NEW ANGLE IAW SRM 51-40-07-02-01. TREATED, PRIMED AND INSTALLED IAW SRM 51-25-10-02-01, 51-21-10-02-01 AND 51-42-05-02-01. APPLIED ALUMINIZED PAINT, ALODINED, PRIMED AND APPLIED CPC IAW SRM 51-21-10-02-01, 51-25-10-02-01, 51-25-15-02-01 AND AMM 51-25-01-390-801.