What was found
LEFT WING RIB AT STA YW-281.019 HAS TOOLING SCRATCHES ON THE INBD SIDE APPROX 6" FORWARD OF THE REAR SPAR. SMOOTHED OUT AFFECTED AREA IAW SRM 51-14-00-02-04. CONFIRMED AREA TO BE CRACK FREE REF NTM 51-00-01-250-801 PT 6. MIN REMAINING THICKNESS .067 REF NTM 51-00-04-910-801 PT 1. MAPPED FOR ENGINEERING. BLENDED AREA IS WITHIN LIMITS IAW RD 8/4-57-1863 RECEIVED FROM ENGINEERING. ROTO PEENED AND APPLIED SURFACE PROTECTION IAW RD 8/4-57-1863. COMPLIED WITH TASK CARD RD 8/4-57-1863.