What was found
FRAME BS 258.5 FLANGES HAVE CORROSION BETWEEN STRINGER 31 AND 33 PORT. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS .039" REF NTM 51-00-04-910-801 PT 1. CONFIRMED CRACK FREE CONDITION OF AFFECTED AREA REF NTM 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD 8/4-53-2344. ALODINED AND PRIMED IAW RD 8/4-53-2344. RESTORED SURFACE PROTECTION ON INTERIOR IAW RD 8/4-53-2344. APPLIED EXT PRIMER SRM 51-25-10-02-01. APPLIED TOPCOAT IAW AMM 51-25-31-370-801.