What was found
STRINGER 24P HAS CORROSION AND CORRODED RIVETS BETWEEN STA X216.000 AND X281.000. CLEANED STRINGER AND REMOVED RIVETS IAW SRM 51-26-00-02-01, 51-42-05-02-01, AND 51-21-00-00-02. BLENDED CORROSION IAW SRM 51-21-00-00-02. VERIFIED CRACK FREE IAW NTM 51-00-06-910-801 PT 1AND 51-00-04-910-801. MIN REMAINING MATERIAL .032. MATERIAL LOSS FOUND WITHIN LIMITS IAW Q400 RD 8/4-53-4617. ALODINED AND PRIMED BLENDED AREAS AS REQUIRED REINSTALLED STRINGER RIVETS IAW RD 8/4-53-4617. RESTORED SURFACE PROTECTION ON INTERIOR IAW RD 8/4-53-4617. APPLIED PRIMER TO EXTERIOR IAW Q400 SRM 51-25-10-02-01. RESTORED EXTERIOR TOP COAT IAW Q400 SRM 51-25-05-02-01.