What was found
FLOORBEAM X32.400 HAS AREA OF CORROSION OTBD OF LT WIRE BUNDLE TRAY. REMOVED FLOOR SUPPORT FOM IAW SRM 51-42-05-02-01. REMOVED CORRROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS .069" REF NTM 51-00-04-910-801 PT 1. BLENDED AREA CONFIRMED CRACK FREE REF NTM 51-00-06-910-801 PT 1. BLENDED AREAS FOUND WITHIN LIMITS IAW RD 8/4-53-4607. APPLIED SURFACE PROTECTION IAW RD 8/4-53-4607. INSTALLED FLOORBOARD SUPPORT IAW SRM 51-42-05-02-01. PAINTED AND APPLIED SURFACE PROTECTION IAW RD 8/4-53-4607, COMPLIED WITH TASK CARD RD 8/4-53-4607.