What was found
OTBD FLOOR SUPPORT FOR WARDROBE FLOOR HAS AREA OF CORROSION FROM STA X-15.000 TO X1.00. REMOVED FLOOR SUPPORT BRACKET FOM IAW SRM 51-42-45-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS .047 REF NTM 51-00-06-910-801 PT 1. CONFIRMED BLENDED AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND IN LIMITS IAW RD 8/4-53-4611. ALODINED AND PRIMED IAW RD 8/4-53-4611. REINSTALLED BRACKET IAW SRM 51-42-05-02-01 AND 51-42-45-02-01. APPLIED SURFACE PROTECTION IAW RD 8/4-53-4611. COMPLIED WITH TASK CARD RD 8/4-53-4611.