What was found
FRAME X196.000 LOWER FLANGES HAVE CORROSION BETWEEN STRINGERS 31S AND 32S. REMOVED 5 RIVETS AND BLENDED CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. FOUND CRACKS IN LOWER FLANGE, CUT AND FABRICATED ANGLE IAW SRM 53-10-15-02-01. FABRICATED ANGLE OUT OF 2024 T3 .050 IAW SRM 53-01-15-02-01. CONFIRMED REPAIR FLANGE AND CUT LINE CRACK FREE REF NTM 51-00-06-910-801 PT 1. ALODINED, PAINTED ANGLE AND FRAME IAW SRM 53-01-15-02-01. INSTALLED ANGLE IAW SRM 53-10-15-02-01. APPLIED CORROSION INHIBITING COMPOUND IAW AMM 51-25-01-390-801. APPLIED TOP COAT IAW SRM 51-25-15-02-01. COMPLIED WITH TASK CARD RD 8/4-53-4634.