What was found
FRAME X94.800, LOWER FLANGES HAVE CORROSION BETWEEN STRINGERS 29P AND 33. REMOVED RIVETS IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS .035 REF NTM 51-00-04-910-801 PT 1. CONFIRMED CRACK FREE CONDITION REF NTM 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND OUT OF LIMITS IAW RD 8/4-53-2344. CUT OUT DAMAGE AND FABRICATED REPAIR IAW RD 8/4-53-017. ALODINED AND PRIMED REPAIR PARTS IAW RD 8/4-53-017. ALODINED AND PRIMED FLANGES IAW RD 8/4-53-2344. INSTALLED FABRICATED PART IAW SRM 51-42-05-02-01. APPLIED ALODINE, PRIMER, ALUMINIZED PAINT AND AV-8 TO INTERIOR IAW SRM 51-21-10-02-01, 51-25-15-02-01 AND AMM 51-25-01-390-801. ALODINED PRIMED AND PAINTED EXTERIOR IAW Q400 SRM 51-21-10-02-01, 51-25-10-02-01 AND SRM 51-25-05-02-01. CONFIRMED WEB CUT LINE 29P-30P CRACK FREE REF NTM 51-00-06-910-801 PT 1.