What was found
STRINGER 24S HAS CORROSION AND CORRODED RIVETS BETWEEN STA X216.000 AND X236.000. REMOVED RIVETS, BLENDED CORROSION REF SRM 51-26-00-02-01, 51-42-05-02-01 AND 51-21-00-00-02. MIN REMAINING THICKNESS NOTED .030 REF NTM 51-00-04-910-801 PT 1. REMOVED CLEAT REF SRM 51-40-15-02-0`1, 51-42-05-02-01. REMOVED DAMAGED STRINGER SECTION REF RD 8/4-53-4619. CONFIRMED AREAS CRACK FREE REF NTM 51-00-06-910-801. FABRICATED SPLICE REPAIR REF RD 8/4-53-4619. FABRICATED STRINGER REPAIR IAW RD 8/4-53-4619. TREATED AND INSTALLED STRINGER AND SPLICE IAW RD 8/4-53-4619. APPLIED ALUMINIZED PAINT IAW SRM 51-25-15-02-01. APPLIED PRIMER AND EXTERIOR TOP COAT IAW SRM 51-25-05-02-01.