What was found
FWD PAX DOOR THRESHOLD PLATE BETWEEN STA X8.00 AND 24.000 HAS AREAS OF CORROSION ON TOP AND BOTTOM SURFACES. REMOVED THRESHOLD FOM IAW SRM 51-42-05-02-01. FOUND TO BE OUT OF LIMITS IAW SRM 53-20-23-02-01. THRESHOLD CHANNEL FOUND TO BE OUT OF LIMITS IAW SRM 53-20-23-02-01. REMOVED CORNER CASTINGS FOM IAW SRM 51-42-45-02-01 AND 51-42-05-02-01. REMOVED THRESHOLD CHANNEL IAW SRM 51-42-05-02-01. MATCH DRILLED THRESHOLD CHANNEL, PLATE IAW SRM 51-40-07-02-01. INSTALLED CHANNEL , PLATE AND CORNERS IAW SRM 51-42-05 AND 51-42-45. APPLIED SURFACE PROTECTION IAW SRM 51-25-15-02-01. PRIMED AND PAINTED IAW SRM 51-25-10-02-01 AND 51-25-15-02-01.