What was found
FRAME BS 714, FLANGES BETWEEN STR 31P-32P BUBBLING PAINT PROBABLE CORROSION. CLEANED FRAME IAW SRM 51-26-00-02-01. REMOVED 1 RIVET AND CORROSION IAW SRM 51-40-07-02-01 AND RD 8/4-53-2344. MIN REMAINING THICKNESS .037" CONFIRMED AREA CRACK FREE REF 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT1. MATERIAL LOSS FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-2344. ALODINED, PRIMED AND INSTALLED 1 RIVET IAW RD 8/4-53-2344. APPLIED ALUMINIZED PAINT IAW RD 8/4-53-2344. APPLIED TOPCOAT IAW SRM 51-25-15-02-01. APPLIED CPC IAW AMM 51-25-01-390-801.