What was found
FRAME 703.6, FLANGE AT STR 24S HAS CORROSION. REMOVED HI LITE AND BLENDED CORROSION IAW SRM 51-40-15-02-01 AND 51-21-00-00-02. MIN REMAINING THICKNESS .046", CONFIRMED CRACK FREE CONDITION REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD 8/4-53-2344. APPLIED ALODINE, PRIMER AND INSTALLED HI LITE IAW RD 8/4-53-2344 AND SRM 51-40-15-02-01. APPLIED TOP COAT AND CPCP IAW RD 8/4-53-2344.