What was found
FRAME X584 FLANGES BETWEEN STR 30P - 33 BUBBLING PAINT PROBABLE CORROSION. CLEANED IAW SRM 51-26-00-02-01. REMOVED RIVETS AND CORROSION IAW RD 8/4-53-2344. MIN REMAINING THICKNESS .046", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND IN LIMITS IAW RD 8/4-53-2344. INSTALLED RIVETS IAW RD 8/4-53-2344. ALODINED, PRIMED AND PAINTED IAW SRM 51-211-10-02-01, 51-25-10-02-01, AND 51-25-15-02-01. APPLIED CPC IAW AMM 51-25-01-390-801.