What was found
FRAME X624, FLANGES BETWEEN STR 29S - 33 BUBBLING PAINT PROBABLE CORROSION. CLEANED IAW SRM 51-26-00-02-01. REMOVED RIVETS AS NESESSARY AND BLENDED CORROSION REF RD 8/4-53-2344. MIN REMAINING THICKNESS .046", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND IN LIMITS IAW RD 8/4-53-2344. ALODINED, PRIMED AND INSTALLED RIVETS IAW RD 8/4-53-2344. APPLIED ALUMINIZED PAINT IAW RD 8/4-53-2344. APPLIED TOP COAT TO EXTERIOR IAW SRM 51-25-05-02-01 AND CPC IAW RD8/4-53-2344.