What was found
FRAME X489.5 FLANGES BETWEEN STRS 29S - 33 BUBBLING PAINT PROBABLE CORROSION. CLEANED AREA, REMOVED FOUR RIVETS AND BLENDED CORROSION IAW RD 8/4-53-2344. REMAINING THICKNESS NOTED .046", CONFIRMED AREA CRACK FREE REF 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND IN LIMITS IAW RD 8/4-53-2344. INSTALLED RIVETS IAW SRM 51-42-05-02-01. ALODINED, PRIMED AND PAINTED IAW SRM 51-21-10-02-01, 51-25-10-02-01, AND 51-25-15-02-01. APPLIED CPC IAW AMM 51-25-01-390-801. PRIMED AND PAINTED RIVETS IAW SRM 51-25-10-02-01 AND 51-25-25-02-01.