What was found
FRAME X301, FLANGES BETWEEN STR 29P - 33 BUBBLING PAINT PROBABLE CORROSION. REMOVED RIVETS IAW SRM 51-42-05-02-01, REMOVED CORROSION IAW RD 8/4-53-2344. MIN REMAINING THICKNESS .037 CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-2344. ALODINED, PRIMED AND INSTALLED RIVETS IAW RD 8/4-53-2344. APPLIED ALUMINIZED PAINT, EXTERIOR TOP COAT AND CPC IAW RD 8/4-53-2344 AND 51-25-05-02-01.