What was found
FRAME X236, FLANGES BETWEEN STRS 28P-33 BUBBLING PAINT PROBABLE CORROSION. CLEANED AREA IAW SRM 51-26-00-02-01. REMOVED RIVETS AND BLENDED CORROSION IAW SRM 51-42-05-02-01 AND RD 8/4-53-2344. MIN REMAINING THICKNESS .038" REF NTM 51-00-04-910-801 PT 1. CONFIRMED CRACK FREE CONDITION REF NTM 51-00-06-910-801 PT 1. MATERIAL LOSS WITHIN LIMITS IAW RD 8/4-53-2344. INSTALLED RIVETS IAW RD 8/4-53-2344. APPLIED PRIMER, ALUMINIZED TOP COAT AND CPC IAW SRM 51-25-10-02-01, 51-25-15-02-01 AND AMM 51-25-01-390-801. APPLIED PRIMER AND PAINT TO EXTERIOR IAW SRM 51-25-05-02-01.