What was found
FRAME X258, FLANGES BETWEEN STRS 25S-26S AND 28S - 32S, BUBBLING PAINT PROBABLE CORROSION. CLEANED IAW SRM 51-26-00-02-01. REMOVED RIVETS PAINT, PRIMER AND CORROSIN IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. NO OTHER CORROSION OR DEFECTS NOTED. MIN REMAINING THICKNESS NOTED .039", CONFIRMED FLANGES CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND IN LIMITS IAW RD 8/4-53-2344. INSTALLED RIVETS IAW RD 8/4-53-2344. CLEANED AND ALODINED FRAME FLANGES IAW SRM 51-21-10-02-01, PRIMED, TOPCOATED AND APPLIED CPC IAW SRM 51-25-10-02-01, AND TASK CARD 531000Q01-60176. APPLIED PRIMER AND TOPCOAT TO EXTERIOR IAW RD 8/4-53-2344.