What was found
FRAME X529, FLANGES BETWEEN STRS 29S-30S AND 31S-32S BUBBLING PAINT PROBABLE CORROSION. CLEANED IAW SRM 51-26-00-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-01. MIN REMAINING THICKNESS .043", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND OUT OF LIMITS. REMOVED DAMAGED FLANGE AND FABRICATED NEW FLANGE IAW RD 8/4-53-017. PERFORMED HFEC NDTM PT 1 TASK 51-00-06-910-801 AND RD 8/4-53-017. ALODINED IAW SRM 51-21-10-02-01 AND PRIMED SRM 51-25-10-02-01. INSTALLED REPAIR ANGLE AND REINSTALLED CROSS BRACES IAW SRM 51-42-05-02-01 AND 51-41-05-00-01. TREATED, PRIMED AND PAINTED IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND RD 8/4-53-017. ALODINED, PRIMED AND TOP COATED EXTERNAL SKIN IAW SRM 51-21-10-02-01, 51-25-10-05-01 AND 51-25-05-02-01.